| TECO-Westinghouse offers an extensive collection of customizable motor modifications. Please select from the listings below which modification is needed to suit your application. |
| FRAME |
LIST PRICE |
| SINGLE ADJUSTMENT |
DOUBLE ADJUSTMENT |
| 140T |
90 |
100 |
| 180T |
110 |
120 |
| 210T |
150 |
160 |
| 250T |
170 |
180 |
| 280T |
180 |
200 |
| 320T |
220 |
240 |
| 360T |
260 |
280 |
| 400T |
440 |
460 |
| 444T-445T |
510 |
540 |
| 447T |
- |
600 |
| 449T |
- |
720 |
| FRAME |
LIST PRICE |
| Contact TWMI |
Contact TWMI |
|
| Bearings RTD's with AUX/BOX |
|
Install 100 Platinum RTD’s on the drive end and non-drive end bearings. Leads are brought out to a separate terminal housing off of the main box. 10 OHM Copper and 120 OHM Nickel RTD’s are available upon request, contact your nearest TECO-Westinghouse representative. |
|
| FRAME |
LIST PRICE |
| 400T-445T |
4,425 |
| 447T-5000 |
4,504 |
|
| Ball Bearings to Roller Bearings |
|
Conversion from drive end ball bearing to drive end roller bearing for belt drive applications. |
|
| BEARING NUMBER |
LIST PRICE |
| 6318-NU318C3 |
3,497 |
| 6320-NU320C3 |
4,144 |
| 6322-NU322C3 |
6,085 |
| 6324-NU324C3 |
7,623 |
| 6326-NU326C3 |
8,271 |
|
| Roller Bearings to Ball Bearings |
|
Conversion from drive end roller bearing to drive end ball bearing for direct-coupled applications . |
|
| BEARING NUMBER |
LIST PRICE |
| NU318-6318C3 |
2,509 |
| NU320-6320C3 |
3,429 |
| NU322-6322C3 |
3,429 |
| NU324-6324C3 |
4,353 |
| NU326-6326C3 |
7,686 |
|
| Cast Iron Fans |
|
Install cast iron fans on TEFC motors. Available for Optim HE Plus and Advantage Plus only. |
|
| FRAME |
LIST PRICE |
| 140T-180T |
371 |
| 210-250T |
398 |
| 280T |
424 |
| 320-360T |
451 |
| 400T |
609 |
| 440T |
741 |
|
| Auxiliary Terminal Box Off Man Box |
|
Add an auxiliary terminal box adjacent to the main terminal box. The auxiliary box will be connected to the main terminal box using 3/4” rigid conduit. Accessory devices are not included. |
|
| FRAME |
LIST PRICE |
| 140T-280T |
625 |
| 320T-360T |
716 |
| 400T-445T |
855 |
| 447T-5000 |
902 |
| 5800-6800 |
1,145 |
|
| Auxiliary Terminal Box F-2 Side |
|
Add an auxiliary terminal box mounted F-2 side of motor. |
|
| FRAME |
LIST PRICE |
| 140T-280T |
702 |
| 320T-360T |
802 |
| 400T-445T |
961 |
| 447T-5000 |
1,010 |
| 5800 |
1,190 |
| 6800 |
1,366 |
|
| F-2 Main Conduit Box Assembly |
|
Change the position of the main terminal box to left-hand side when facing the non-drive end.
NOTE:
Contact your local TECO-Westinghouse representative. |
|
| FRAME |
LIST PRICE |
| 140T-280T |
275 |
| 320T |
436 |
| 360T |
526 |
| 400T |
605 |
| 444T-447T |
665 |
| 449 |
775 |
| 5000-5800 |
3,130 |
|
| Breather / Drain |
|
Add breather type anti-condensation drains to TEFC motors.
NOTE:
This modification is not applicable to Advantage Plus and Optim TEXP-HE.
|
|
| FRAME |
LIST PRICE |
| 140-280T |
397 |
| 320-400T |
432 |
| 440T |
525 |
|
| Drip Cover |
|
Install a drip cover to TEFC motors for vertical mounted, shaft-down applications. |
|
| FRAME |
LIST PRICE |
| 140T-250T |
1,040 |
| 280T |
1,310 |
| 320T-400T |
1,700 |
| 440T |
2,316 |
|
| Ground Lug |
|
Install an additional ground lug on a motor foot, unless otherwise specified. |
|
| FRAME |
LIST PRICE |
| 140T-280T |
276 |
| 320T-400T |
415 |
| 440T |
553 |
| 5000-6800 |
713 |
|
| INPRO Seal™ |
|
Install Inpro non-contacting labyrinth seals on Advantage Plus Motors.
NOTE:
- Subject to change without notice.
- Each kit includes motor end bell or outer bearing cap and INPRO SEAL™ to convert Advantage Plus IEEE Ready motors.
- Only outer bearing cap is supplied for Frames 400TS and 400T at drive end.
- For corrosive atmospheres, contact your TECO-Westinghouse representative.
- If motor is to be mounted vertically advise TWMI for a special vertical INPRO SEAL™.
NOTE:
INPRO SEAL™ is a registered trademark of INPRO SEAL COMPANY.
|
|
| FRAME |
INSTALLED |
SUPPLIED LOOSE |
DRIVE END
LIST PRICE |
NON DRIVE
END LIST PRICE |
DRIVE END
LIST PRICE |
NON DRIVE END
LIST PRICE |
| 140T |
278 |
278 |
193 |
193 |
| 180T |
310 |
310 |
214 |
214 |
| 210T |
410 |
410 |
284 |
284 |
| 250T |
459 |
363 |
318 |
251 |
| 280TS |
612 |
534 |
426 |
368 |
| 280T |
612 |
534 |
426 |
368 |
| 320T-320TS |
663 |
663 |
459 |
462 |
| 360TS |
663 |
663 |
459 |
462 |
| 360T |
720 |
726 |
499 |
501 |
| 400TS |
920 |
760 |
500 |
542 |
| 400T |
962 |
760 |
658 |
501 |
|
| Extended Leads |
|
Add 12” to the length of motor leads. |
|
| FRAME |
LIST PRICE |
| 400T |
1,102 |
| 440T |
1,475 |
|
| Low Noise Kit |
|
Reduce motor noise to a sound pressure level of <85dBA @ 1m per IEEE-85 standards. |
|
| FRAME |
LIST PRICE |
| 447T-449T/2P |
3,030 |
| 5000/2P |
4,072 |
| 5000/4P |
3,635 |
| 5800/2P |
4,861 |
| 5800/4P |
4,593 |
| 6800/2P |
6,789 |
| 6800/4P |
7,050 |
|
| C-Flange / D-Flange |
|
Add C-flange or D-flange to TEFC, TEXP or ODP motors. Flanges may be sold separately as shown below.
NOTE:
- Prices subject to change without notice.
- All Kits FOB shipping point, minimum billing is $25.00 per order. Kits can be combined with motor stock orders.
- TEXP HE C-Flanges can only be installed by a CSA approved (for XP) repair facility and the repair facility assumes all product warranty.
- Please specify model name when ordering.
- D-Flange for Optim HE PLUS not available for 140-210 frame sizes.
- D-Flange for TEXP not available.
|
|
| FRAME |
OPTIM HE PLUS / EPACT |
TEXP HE |
| INSTALLED LIST PRICE |
SUPPLIED LOOSE LIST PRICE |
INSTALLED LIST PRICE |
SUPPLIED LOOSE LIST PRICE |
| 140T |
192 |
77 |
317
|
103 |
| 180T |
218 |
103 |
383
|
128 |
| 210T |
254 |
139 |
430
|
180 |
| 250T |
295 |
180 |
593
|
302 |
| 280T-280TS |
372 |
257 |
687
|
334 |
| 320T-320TS |
464 |
349 |
843
|
452 |
| 360T-360TS |
551 |
436 |
1,043
|
565 |
| 400T-400TS |
895 |
706 |
1,260 |
910 |
| 444-445 |
1,552 |
1,437 |
2,027
|
1,540 |
| 447-449 |
1,552 |
1,437 |
- |
- |
| FRAME |
ODP |
ADVANTAGE PLUS |
| INSTALLED LIST PRICE |
SUPPLIED LOOSE LIST PRICE |
INSTALLED LIST PRICE |
SUPPLIED LOOSE LIST PRICE |
| CAST IRON |
ROLLED STEEL |
CAST IRON |
ROLLED STEEL |
| 56 |
- |
157 |
- |
42 |
- |
- |
| 140T |
- |
167 |
- |
52 |
197 |
82 |
| 180T |
- |
182 |
- |
67 |
228 |
113 |
| 210T |
- |
192 |
- |
77 |
269 |
154 |
| 250T |
259 |
250 |
144 |
134 |
310 |
195 |
| 280T-280TS |
310 |
320 |
195 |
206 |
397 |
282 |
| 320T-320TS |
423 |
- |
308 |
- |
500 |
385 |
| 360T-360TS |
551 |
- |
436 |
- |
577 |
462 |
| 400T-400TS |
895 |
- |
539 |
- |
996 |
806 |
| 444-445 |
1,321 |
- |
1,206 |
- |
1,655 |
1,540 |
| 447-449 |
1,450 |
- |
1,335 |
- |
1,655 |
1,540 |
|
| C-Flange Kit for Farm Duty Motors |
|
Add C-flange to Farm Duty motors. |
|
| FRAME |
C-FLANGE MOD FARM DUTY LIST PRICE |
| 56 |
46 |
| 145T |
77 |
| 182T |
103 |
| 184T |
103 |
| 213T |
139 |
| 215T |
139 |
|
| C-Flange Kit for Aluminum Frame NEMA Motors |
|
Add C-flange to Aluminum Frame NEMA motors. |
|
| FRAME |
C-FLANGE MOD ALUMINUM FRAME NEMA LIST PRICE |
| 56 |
36 |
| 143T |
51 |
| 145T |
51 |
| 182T |
68 |
| 184T |
68 |
| 213T |
77 |
| 215T |
77 |
|
| P-Base Kits |
|
Add P-Base to TEFC motors.
NOTE:
Only standard T or TS shaft extension will be supplied. For a ring type shaft contact your TWMI representative. |
|
| FRAME |
LIST PRICE |
| 320T-320TS |
Contact TWMI |
| 360T-360TS |
Contact TWMI |
| 400T-400TS |
Contact TWMI |
| 444T-449T |
Contact TWMI |
|
| Remove Mounting Feet |
|
Remove mounting feet from motor. C-flange or other mounting faces are sold separately. |
|
| FRAME |
LIST PRICE |
| 140T-280T |
Contact TWMI |
| 320T |
Contact TWMI |
| 360T |
Contact TWMI |
| 400T |
Contact TWMI |
| 440T |
Contact TWMI |
|
| Stainless Steel Auxiliary Nameplates |
|
Provide a stainless steel nameplate with customer specified data. |
|
| FRAME |
LIST PRICE |
| 140T-440T |
149 |
| 5000-6800 |
225 |
|
| Custom Exterior Colour |
|
Paint motor using customer specified exterior paint. |
|
| FRAME |
LIST PRICE |
| 140T-210T |
Contact TWMI |
| 250T-360T |
Contact TWMI |
| 400T |
Contact TWMI |
| 440T-5000 |
Contact TWMI |
|
| Epoxy Exterior Coat |
|
Apply one coat of epoxy paint to motor external surfaces. |
|
| FRAME |
LIST PRICE |
| 140T-280T |
356 |
| 320T-360T |
605 |
| 400T |
812 |
| 440T |
935 |
| 5000 |
983 |
| 5800 |
1,302 |
| 6800 |
1,458 |
|
| Epoxy Interior Coat |
|
Apply one coat of epoxy paint to motor internal surfaces. |
|
| FRAME |
LIST PRICE |
| 140T-360T |
Contact TWMI |
| 400T-440T |
Contact TWMI |
|
| Change Fan Rotation from CCW to CW |
|
This modification only applies to 3600RPM motors in 5000/5800/6800 TEFC frames. This modification will change rotation to CW direction facing the drive-end (contact a TWMI representative for fan only price). |
|
| FRAME |
LIST PRICE |
| 5000-6800 |
4,860 |
|
| Double Shaft |
|
Add double shaft extension to motor. Shaft dimensions to be specified by customer. |
|
| FRAME |
LIST PRICE |
| 140T-280T |
Contact TWMI |
| 320T-360T |
Contact TWMI |
| 400T |
Contact TWMI |
| 440T |
Contact TWMI |
|
| Drill and Tap Shaft |
|
Drill and tap a threaded hole into the motor shaft extension. Hole diameter and thread to be specified by customer. |
|
| FRAME |
LIST PRICE |
| 140T-210T |
Contact TWMI |
| 250T-320T |
Contact TWMI |
| 360T-400T |
Contact TWMI |
| 440T |
Contact TWMI |
|
| Shorten Shaft |
|
Modify shaft length, diameter, key length, and keyway to TS dimensions (EX. 365T to 365TS). |
|
| FRAME |
LIST PRICE |
| 140T-210T |
961 |
| 250T-280T |
1,723 |
| 320T |
1,881 |
| 360T |
2,225 |
| 400T |
2,464 |
| 440T |
3,127 |
|
| 120 or 240V Space Heater (Low Temp.) |
|
Install space heater. Auxiliary terminal boxes are included. |
|
| FRAME |
LIST PRICE |
| 140T-210T |
945 |
| 250T |
1,087 |
| 280T-360T |
1,339 |
| 400T |
1,593 |
| 440T |
1,858 |
| 5000 |
2,095 |
| 5800 |
2,182 |
| 6800 |
2,491 |
|
| 100 OHM RTD's 1/Phase |
|
Surface mount (3) RTD’s on stator end turns. Embedded RTD’s are available. Contact your TECO-Westinghouse representative for details. Auxiliary terminal boxes are priced separately. |
|
| FRAME |
LIST PRICE |
| 400T |
1,654 |
| 440T |
2,095 |
| 5000 |
2,333 |
| 5800 |
2,491 |
| 6800 |
2,733 |
|
| 100 OHM RTD's 2/Phase |
|
Surface mount (6) RTD’s on stator end turns. Embedded RTD’s are available. Contact your TECO-Westinghouse representative for details. Auxiliary terminal boxes are priced separately. |
|
| FRAME |
LIST PRICE |
| 400T-440T |
3,273 |
| 5000 |
5,433 |
|
| Thermistors, 1/Phase |
|
Surface mount (3) Thermistors on stator end turns. Embedded Thermistors are available. Contact your TECO-Westinghouse representative for details. Auxiliary terminal boxes are priced separately. |
|
| FRAME |
LIST PRICE |
| 140T-180T |
912 |
| 210T-320T |
1,075 |
| 360T |
1,196 |
| 400T |
1,246 |
| 440T |
1,512 |
| 5000 |
1,595 |
| 5800 |
1,675 |
| 6800 |
1,998 |
|
| Unwitnessed Commercial Test |
|
Test consisting of the following:
- Measure cold winding resistance
- Measure no load voltage
- Measure no load current
- Measure no load watts
- Measure no load vibration
- Measure no load RPM
- Hi-pot dielectric test
- Check any auxiliary devices
- Check current balance
|
|
| FRAME |
LIST PRICE |
| 360T |
Contact TWMI |
| 400T |
Contact TWMI |
| 440T |
Contact TWMI |
|
| Unwitnessed Complete Test |
|
Test consisting of the following:
- Measure cold winding resistance
- Measure no load voltage
- Measure no load current
- Measure no load watts
- Measure no load vibration
- Measure no load RPM
- Hi-pot dielectric test
- Check any auxiliary devices
- Check current balance
- Full load heat run
- Calculate percent slip
- Measure 3 phase locked rotor amps
- Measure locked rotor torque
- Measure breakdown torque
- Measure efficiency and power factor at full load, 3/4 load and 1/2 load.
- Calculate stray load loss
|
|
| FRAME |
LIST PRICE |
| 140T-250T |
Contact TWMI |
| 280T-360T |
Contact TWMI |
| 440T |
Contact TWMI |
|
| IEEE 841 Vibration Check |
|
Test motor for compliance with IEEE 841-2001, 6.9 standards. |
|
| FRAME |
LIST PRICE |
| 140T |
169 |
| 180T |
171 |
| 210T |
171 |
| 250T |
171 |
| 280T |
171 |
| 320T |
245 |
| 360T |
320 |
| 400T |
368 |
| 444T-445T |
507 |
| 447T-449T |
586 |
|
 |
|